Technical parameters
Depending on the needs of users, we can offer wastewater treatment plants with different performance:
Model | Number of users | Efficiency, m3/d | Efficiency, m3/h | Average load of pollutants, kg BDS5/d | Maximum load of pollutants, kg BDS5/d | Capacity, m3 | Compressor efficiency, l/min |
WTP-1 | 1-5 | 0,80 | 0,16 | 0,245 | 0,31 | 1,67 | 80 |
WTP-2 | 3-8 | 1,30 | 0,26 | 0,41 | 0,47 | 2,54 | 100 |
WTP-3 | 7-12 | 1,90 | 0,37 | 0,595 | 0,68 | 3,58 | 150 |
WTP-4 | 10-18 | 2,80 | 0,523 | 0,86 | 1,00 | 5,3 | 200 |
WTP-5 | 17-26 | 4,00 | 0,695 | 1,245 | 1,44 | 7,68 | 300 |
Model | H1 | H2 | H3 | H4 | H5 | D1 | D2 | D3 |
WTP-1 | 2060 | 460 | 1600 | 1466 | 1296 | 900 | 1740 | 110 |
WTP-2 | 2320 | 460 | 1860 | 1716 | 1511 | 900 | 1900 | 110 |
WTP-3 | 2400 | 460 | 1940 | 1796 | 1551 | 900 | 2300 | 110 |
WTP-4 | 2630 | 460 | 2170 | 1976 | 1736 | 900 | 2560 | 160 |
WTP-5 | 2940 | 460 | 2480 | 2286 | 2001 | 900 | 2820 | 160 |
Wastewater treatment plants are installed taking into account the requirements of the structural technical project, the provisions of the construction technical regulations, the principles established by the wastewater management regulation, as well as wastewater management infrastructure development solutions, approved by the local government, and the limits of agglomerations.
The place for installation is chosen in order to have the least possible impact on the environment and to ensure convenient access for the sanitation machine to perform technical service of the device.
Depending on the projected installation conditions / location of the treated water outlet, devices can be completed with wastewater/water pumping stations, infiltration wells and other components, which are purchased separately!